Produkter
Specifications |
FX3U-16CCL-M 1 |
FX5-CCL-MS | ||
---|---|---|---|---|
Applicable for |
Base units FX3G, FX3GC, FX3GE, FX3U, FX3UC, FX5U, FX5UC |
Base units FX5U, FX5UC | ||
Module type |
Master station |
Master/Intelligent device station | ||
Link points per station |
I/O points |
32 | ||
Register |
8 | |||
Max. number of I/O points |
FX3G/FX3GC/FX3GE: 32 x nbr. of stations ≤128 FX3U/FX3UC: 32 x nbr. of stations ≤256 2 |
768 | ||
Number of connectable modules |
Max. 16 |
Max. 24 | ||
Power supply |
5 V DC |
— | ||
24 V DC |
240 mA |
100 mA | ||
Related I/O points |
8 | |||
Weight |
kg |
0.4 |
0.3 | |
Dimensions (WxHxD) |
mm |
55x90x87 |
50x90x83 | |
Order information |
Art. no. |
248224 |
312299 |
- To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.More informations about CC-Link are available in various other publications from Mitsubishi Electric.
- Total of I/O points in base unit and extension units within the CC-Link network ≤384.Notes: Please refer to manual for slave functionality.For the connection of a FX3U-16CCL-M to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Specifications |
FX3U-64CCL | ||
---|---|---|---|
Module type |
Intelligent device station | ||
Link points per station |
I/O points |
128 (Occupying 1 station with octuple expanded cyclic setting) | |
Register |
32 (Occupying 1 station with octuple expanded cyclic setting) | ||
Max. transmission speed |
10 Mbps | ||
Related I/O points |
8 | ||
Power supply |
24 V DC |
24 V DC/220 mA | |
Weight |
kg |
0.3 | |
Dimensions (WxHxD) |
mm |
55x90x87 | |
Order information |
Art. no. |
217915 |
Notes : When attaching the FX3U-64CCL to a FX3UC/FX3GC base unit, the FX2NC-CNV-IF interface converter or the FX3UC-1PS-5V power supply unit is required. More informations about CC-Link are available in various other publications from Mitsubishi Electric. For the connection of a FX3U-64CC to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Specifications |
FX5-CCLIEF | ||
---|---|---|---|
Station type |
Intelligent device station | ||
Communication speed |
1 Gbps | ||
Max. number of I/O points |
RX |
384 points, 48 bytes | |
RY |
384 points, 48 bytes | ||
RWr |
1024 points, 2048 bytes 1 | ||
RWw |
1024 points, 2048 bytes 1 | ||
Power supply |
5 V DC |
10 mA | |
24 V DC |
230 mA (external power supply) | ||
Related I/O points |
8 | ||
Weight |
kg |
0.3 | |
Dimensions (WxHxD) |
mm |
50x90x103 | |
Order information |
Art. no. |
297444 |
- 256 points (512 bytes) when the master station is in high-speed mode.
Specifications |
FX5-ASL-M | ||
---|---|---|---|
Module type |
AnyWireASLINK system master module | ||
Max. number of I/O points |
384 | ||
Number of connectable modules |
128 | ||
Power supply |
5 V DC |
200 mA | |
24 V DC |
100 mA | ||
Related I/O points |
8 | ||
Weight |
kg |
0.2 | |
Dimensions (WxHxD) |
mm |
40x90x83 (97.3 with connector) | |
Order information |
Art. no. |
312300 |
Specifications |
FX5-485ADP | ||
---|---|---|---|
Transmission standard |
Conforming to RS485 and RS422 standards | ||
Communication speed* |
bps |
300/600/1200/2400/4800/9600/19200/38400/57600/115200 | |
Max. communication distance |
m |
1200 m | |
External device connection method |
Terminal block | ||
Power supply |
5 V DC |
20 mA (from base unit) | |
24 V DC |
30 mA (from base unit) | ||
Related I/O points |
0 | ||
Weight kg |
0.08 | ||
Dimensions (WxHxD) |
mm |
17.6x106x74 | |
Order information |
Art. no. |
280514 |
* The communication method and communication speed vary depending upon the communication type.
Specifications |
FX5-232ADP | ||
---|---|---|---|
Transmission standard |
Conforming to RS232C standard | ||
Communication speed* |
bps |
300/600/1200/2400/4800/9600/19200/38400/57600/115200 | |
Max. transmission distance |
15 m | ||
External device connection method |
9 pole D-SUB connector (male) | ||
Power supply |
5 V DC |
30 mA (from base unit) | |
24 V DC |
30 mA (from base unit) | ||
Related I/O points |
0 | ||
Weight |
kg |
0.08 | |
Dimensions (WxHxD) |
mm |
17.6x106x74 | |
Order information |
Art. no. |
280513 |
* The communication method and communication speed vary depending upon the communication type.
Network module for Profibus DP
Specifications |
FX5-DP-M | |
---|---|---|
Applicable for |
Base units FX5U, FX5UC | |
Module type |
Master station | |
Transmission type |
Bus network | |
Transmission data |
32 byte/slave (normal service mode) 244 byte/slave (extended service mode) | |
Interface |
Profibus DP (with 9 pole D-SUB connector) | |
Max. number of master per configuration |
Max. 1 | |
Repeaters |
3 | |
Max. number of slaves |
64 | |
Communications speed |
Profibus standard | |
Communications distance m |
Max. 1200 (depends on communication speed) | |
Communication cable |
Profibus cable with 9-pin D-SUB connector | |
Power supply |
5 V DC |
— |
24 V DC |
150 mA (from base unit) | |
Related I/O points |
8 | |
Weight |
kg |
0.2 |
Dimensions (WxHxD) |
mm |
40x90x85.3 |
Order information |
Art. no. |
409822 |
Accessories |
Profibus connector up to 12 Mbaud: PROFICON-PLUS, art. no. 140008 or PROFICON-PLUS-PG, art. no. 140009 |
Network module for Ethernet
Specifications |
FX5-ENET | ||
---|---|---|---|
Applicable for |
Base units FX5U, FX5UC | ||
Protocol |
TCP/IP, UDP | ||
Communication mode |
Full-duplex/half-duplex | ||
No. of simultaneous open connections |
8 | ||
Fixed buffer communication |
1023 word x 8 | ||
Communication with mail server |
SMTP, POP3 | ||
Interface |
IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT) | ||
CC-Link IE Field Network Basic |
Master | ||
Connector |
2xRJ45 | ||
Max. transfer rate |
100 Mbits/s, 10 Mbit/s | ||
Max. segment length |
m |
100 | |
Cable |
CAT5 STP or 3 STP | ||
Power supply |
5 V DC |
— | |
24 V DC |
110 mA (from base unit) | ||
Related I/O points |
8 | ||
Weight |
kg |
0.2 | |
Dimensions (WxHxD) |
mm |
40x90x83 | |
Order information |
Art. no. |
409823 |
Note: To connect this module to a FX3UC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required .
Network module for EtherNet/IP
Specifications |
FX5-ENET/IP EtherNet/IP communications |
FX5-ENET/IP Ethernet communications | ||
---|---|---|---|---|
Number of ports |
2 1 | |||
Number of connectable units |
1 module | |||
Applicable engineering tool |
GX Works3: Ver. 1.050C or later, EtherNet/IP Configuration Tool for FX5-ENET/IP: Ver. 1.00A or later | |||
Protocol type |
— |
Socket communication | ||
Number of connections |
32 2 |
Total of 32 connections 3 | ||
Transmission specification |
Communication mode |
Full-duplex |
Full-duplex/half-duplex | |
Max. segment lengthm |
100 4 | |||
Connection cable 5 |
100BASE-TX |
100BASE-TX, 10BASE-T | ||
Power supply |
5 V DC |
— | ||
24 V DC |
110 mA (from base unit) | |||
Related I/O points |
8 | |||
Weight |
kg |
0.2 | ||
Dimensions (WxHxD) |
mm |
40x90x83 | ||
Order information |
Art. no. |
409824 |
- Since the IP address is shared by two ports, only one address can be set.
- The total number of connections for Class 3 communications and UCMM communications is 32.
- Up to 32 external devices can access one FX5-ENET/IP module at the same time.
- For maximum segment length (length between hubs), consult the manufacturer of the hub used.
- A straight/cross cable can be used.
Network module for CANopen
Specifications |
FX3U-CAN | ||
---|---|---|---|
Module type |
CANopen master | ||
CANopen communication standard |
CiA 301 V4.2, CiA 302 V4.1, CiA 305 V2.2 | ||
CANopen Lift application profile mode |
CiA 417 V2.1 | ||
CANopen PLC device profile mode |
CiA 405 V2.0 | ||
Max. number of modules that can be connected to the network |
30 without repeater; 127 with repeater | ||
Station numbers |
1–127 | ||
Supported communication speeds |
kbps |
10, 20, 50, 125, 250, 500, 800, 1000 | |
Status displays |
RUN, Error, Power, Network status | ||
Power supply |
5 V DC |
290 mA | |
24 V DC |
— | ||
Related I/O points |
8 | ||
Weight |
kg |
0.2 | |
Dimensions (WxHxD) |
mm |
43x90x88.7 | |
Order information |
Art. no. |
252845 |
Notes: To connect this module to a FX3UC/FX3GC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required. For the connection of a FX3U-CAN to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Network module for SAE J1939
Specifications |
FX3U-J1939 |
---|---|
Communication standard version |
SAE J1939 |
Network node size |
SAE J1939: 2–30 |
Communication method |
Cyclic, acyclic or request driven (user configurable) |
CAN layer-2 communication |
Send and receive |
Max. cable length m |
5000 |
Baud rates kbit/s |
10, 20, 50, 100, 125, 250, 500, 800, 1000 |
Power supply |
24 V DC/110 mA (from base unit) |
Weight kg |
0.2 |
Dimensions (WxHxD) mm |
43x90x95 |
Order information Art. no. |
254276 |
Note: To connect this module to a FX3UC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
Interface adapters
Specifications |
FX5-232-BD |
FX5-485-BD |
FX5-422-BD-GOT | |
---|---|---|---|---|
Applicable for |
Base units FX5U |
Base units FX5U |
Base units FX5U | |
Interface |
RS232C with 9 pole D-SUB connector |
RS485 |
RS422 with 8 pole mini DIN connector | |
Power supply |
5 V DC/20 mA (from base unit) |
5 V DC/20 mA (from base unit) |
5 V DC/20 mA (from base unit) | |
Related I/O points |
— |
— |
— | |
Weight |
kg |
0.02 |
0.02 |
0.02 |
Dimensions (WxHxD) |
mm |
38x51.4x18.2 |
38x51.4x30.5 |
38x51.4x15.4 |
Order information |
Art. no. |
280511 |
280512 |
280515 |
Specifications |
FX3U-16CCL-M 1 |
FX5-CCL-MS | ||
---|---|---|---|---|
Applicable for |
Base units FX3G, FX3GC, FX3GE, FX3U, FX3UC, FX5U, FX5UC |
Base units FX5U, FX5UC | ||
Module type |
Master station |
Master/Intelligent device station | ||
Link points per station |
I/O points |
32 |
32 | |
Register |
8 |
8 | ||
Max. number of I/O points |
FX3G/FX3GC/FX3GE: 32 x nbr. of stations ≤128 FX3U/FX3UC: 32 x nbr. of stations ≤256 2 |
768 | ||
Number of connectable modules |
Max. 16 |
Max. 24 | ||
Power supply |
5 V DC |
— |
— | |
24 V DC |
240 mA |
100 mA | ||
Related I/O points |
8 |
8 | ||
Weight |
kg |
0.4 |
0.3 | |
Dimensions (WxHxD) |
mm |
55x90x87 |
50x90x83 | |
Order information |
Art. no. |
248224 |
312299 |
- To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.More informations about CC-Link are available in various other publications from Mitsubishi Electric.
- Total of I/O points in base unit and extension units within the CC-Link network ≤384.Notes: Please refer to manual for slave functionality.For the connection of a FX3U-16CCL-M to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Specifications |
FX3U-64CCL | |||
---|---|---|---|---|
Module type |
Intelligent device station | |||
Link points per station |
I/O points |
128 (Occupying 1 station with octuple expanded cyclic setting) | ||
Register |
32 (Occupying 1 station with octuple expanded cyclic setting) | |||
Max. transmission speed |
10 Mbps | |||
Related I/O points |
8 | |||
Power supply |
24 V DC |
24 V DC/220 mA | ||
Weight |
kg |
0.3 | ||
Dimensions (WxHxD) |
mm |
55x90x87 | ||
Order information |
Art. no. |
217915 |
Notes : When attaching the FX3U-64CCL to a FX3UC/FX3GC base unit, the FX2NC-CNV-IF interface converter or the FX3UC-1PS-5V power supply unit is required. More informations about CC-Link are available in various other publications from Mitsubishi Electric. For the connection of a FX3U-64CC to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Specifications |
FX5-CCLIEF | |||
---|---|---|---|---|
Station type |
Intelligent device station | |||
Communication speed |
1 Gbps | |||
Max. number of I/O points |
RX |
384 points, 48 bytes | ||
RY |
384 points, 48 bytes | |||
RWr |
1024 points, 2048 bytes 1 | |||
RWw |
1024 points, 2048 bytes 1 | |||
Power supply |
5 V DC |
10 mA | ||
24 V DC |
230 mA (external power supply) | |||
Related I/O points |
8 | |||
Weight |
kg |
0.3 | ||
Dimensions (WxHxD) |
mm |
50x90x103 | ||
Order information |
Art. no. |
297444 |
- 256 points (512 bytes) when the master station is in high-speed mode.
Specifications |
FX5-ASL-M | |||
---|---|---|---|---|
Module type |
AnyWireASLINK system master module | |||
Max. number of I/O points |
384 | |||
Number of connectable modules |
128 | |||
Power supply |
5 V DC |
200 mA | ||
24 V DC |
100 mA | |||
Related I/O points |
8 | |||
Weight |
kg |
0.2 | ||
Dimensions (WxHxD) |
mm |
40x90x83 (97.3 with connector) | ||
Order information |
Art. no. |
312300 |
Specifications |
FX5-485ADP | |||
---|---|---|---|---|
Transmission standard |
Conforming to RS485 and RS422 standards | |||
Communication speed* |
bps |
300/600/1200/2400/4800/9600/19200/38400/57600/115200 | ||
Max. communication distance |
m |
1200 m | ||
External device connection method |
Terminal block | |||
Power supply |
5 V DC |
20 mA (from base unit) | ||
24 V DC |
30 mA (from base unit) | |||
Related I/O points |
0 | |||
Weight kg |
0.08 | |||
Dimensions (WxHxD) |
mm |
17.6x106x74 | ||
Order information |
Art. no. |
280514 |
* The communication method and communication speed vary depending upon the communication type.
Specifications |
FX5-232ADP | |||
---|---|---|---|---|
Transmission standard |
Conforming to RS232C standard | |||
Communication speed* |
bps |
300/600/1200/2400/4800/9600/19200/38400/57600/115200 | ||
Max. transmission distance |
15 m | |||
External device connection method |
9 pole D-SUB connector (male) | |||
Power supply |
5 V DC |
30 mA (from base unit) | ||
24 V DC |
30 mA (from base unit) | |||
Related I/O points |
0 | |||
Weight |
kg |
0.08 | ||
Dimensions (WxHxD) |
mm |
17.6x106x74 | ||
Order information |
Art. no. |
280513 |
* The communication method and communication speed vary depending upon the communication type.
Network module for Profibus DP
Specifications |
FX5-DP-M | ||
---|---|---|---|
Applicable for |
Base units FX5U, FX5UC | ||
Module type |
Master station | ||
Transmission type |
Bus network | ||
Transmission data |
32 byte/slave (normal service mode) 244 byte/slave (extended service mode) | ||
Interface |
Profibus DP (with 9 pole D-SUB connector) | ||
Max. number of master per configuration |
Max. 1 | ||
Repeaters |
3 | ||
Max. number of slaves |
64 | ||
Communications speed |
Profibus standard | ||
Communications distance m |
Max. 1200 (depends on communication speed) | ||
Communication cable |
Profibus cable with 9-pin D-SUB connector | ||
Power supply |
5 V DC |
— | |
24 V DC |
150 mA (from base unit) | ||
Related I/O points |
8 | ||
Weight |
kg |
0.2 | |
Dimensions (WxHxD) |
mm |
40x90x85.3 | |
Order information |
Art. no. |
409822 | |
Accessories |
Profibus connector up to 12 Mbaud: PROFICON-PLUS, art. no. 140008 or PROFICON-PLUS-PG, art. no. 140009 |
Network module for Ethernet
Specifications |
FX5-ENET | |||
---|---|---|---|---|
Applicable for |
Base units FX5U, FX5UC | |||
Protocol |
TCP/IP, UDP | |||
Communication mode |
Full-duplex/half-duplex | |||
No. of simultaneous open connections |
8 | |||
Fixed buffer communication |
1023 word x 8 | |||
Communication with mail server |
SMTP, POP3 | |||
Interface |
IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT) | |||
CC-Link IE Field Network Basic |
Master | |||
Connector |
2xRJ45 | |||
Max. transfer rate |
100 Mbits/s, 10 Mbit/s | |||
Max. segment length |
m |
100 | ||
Cable |
CAT5 STP or 3 STP | |||
Power supply |
5 V DC |
— | ||
24 V DC |
110 mA (from base unit) | |||
Related I/O points |
8 | |||
Weight |
kg |
0.2 | ||
Dimensions (WxHxD) |
mm |
40x90x83 | ||
Order information |
Art. no. |
409823 |
Note: To connect this module to a FX3UC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required .
Network module for EtherNet/IP
Specifications |
FX5-ENET/IP EtherNet/IP communications |
FX5-ENET/IP Ethernet communications | ||
---|---|---|---|---|
Number of ports |
2 1 |
2 1 | ||
Number of connectable units |
1 module |
1 module | ||
Applicable engineering tool |
GX Works3: Ver. 1.050C or later, EtherNet/IP Configuration Tool for FX5-ENET/IP: Ver. 1.00A or later |
GX Works3: Ver. 1.050C or later, EtherNet/IP Configuration Tool for FX5-ENET/IP: Ver. 1.00A or later | ||
Protocol type |
— |
Socket communication | ||
Number of connections |
32 2 |
Total of 32 connections 3 | ||
Transmission specification |
Communication mode |
Full-duplex |
Full-duplex/half-duplex | |
Max. segment lengthm |
100 4 |
100 4 | ||
Connection cable 5 |
100BASE-TX |
100BASE-TX, 10BASE-T | ||
Power supply |
5 V DC |
— |
— | |
24 V DC |
110 mA (from base unit) |
110 mA (from base unit) | ||
Related I/O points |
8 |
8 | ||
Weight |
kg |
0.2 |
0.2 | |
Dimensions (WxHxD) |
mm |
40x90x83 |
40x90x83 | |
Order information |
Art. no. |
409824 |
409824 |
- Since the IP address is shared by two ports, only one address can be set.
- The total number of connections for Class 3 communications and UCMM communications is 32.
- Up to 32 external devices can access one FX5-ENET/IP module at the same time.
- For maximum segment length (length between hubs), consult the manufacturer of the hub used.
- A straight/cross cable can be used.
Network module for CANopen
Specifications |
FX3U-CAN | |||
---|---|---|---|---|
Module type |
CANopen master | |||
CANopen communication standard |
CiA 301 V4.2, CiA 302 V4.1, CiA 305 V2.2 | |||
CANopen Lift application profile mode |
CiA 417 V2.1 | |||
CANopen PLC device profile mode |
CiA 405 V2.0 | |||
Max. number of modules that can be connected to the network |
30 without repeater; 127 with repeater | |||
Station numbers |
1–127 | |||
Supported communication speeds |
kbps |
10, 20, 50, 125, 250, 500, 800, 1000 | ||
Status displays |
RUN, Error, Power, Network status | |||
Power supply |
5 V DC |
290 mA | ||
24 V DC |
— | |||
Related I/O points |
8 | |||
Weight |
kg |
0.2 | ||
Dimensions (WxHxD) |
mm |
43x90x88.7 | ||
Order information |
Art. no. |
252845 |
Notes: To connect this module to a FX3UC/FX3GC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required. For the connection of a FX3U-CAN to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Network module for SAE J1939
Specifications |
FX3U-J1939 | |
---|---|---|
Communication standard version |
SAE J1939 | |
Network node size |
SAE J1939: 2–30 | |
Communication method |
Cyclic, acyclic or request driven (user configurable) | |
CAN layer-2 communication |
Send and receive | |
Max. cable length m |
5000 | |
Baud rates kbit/s |
10, 20, 50, 100, 125, 250, 500, 800, 1000 | |
Power supply |
24 V DC/110 mA (from base unit) | |
Weight kg |
0.2 | |
Dimensions (WxHxD) mm |
43x90x95 | |
Order information Art. no. |
254276 |
Note: To connect this module to a FX3UC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
Interface adapters
Specifications |
FX5-232-BD |
FX5-485-BD |
FX5-422-BD-GOT | |
---|---|---|---|---|
Applicable for |
Base units FX5U |
Base units FX5U |
Base units FX5U | |
Interface |
RS232C with 9 pole D-SUB connector |
RS485 |
RS422 with 8 pole mini DIN connector | |
Power supply |
5 V DC/20 mA (from base unit) |
5 V DC/20 mA (from base unit) |
5 V DC/20 mA (from base unit) | |
Related I/O points |
— |
— |
— | |
Weight |
kg |
0.02 |
0.02 |
0.02 |
Dimensions (WxHxD) |
mm |
38x51.4x18.2 |
38x51.4x30.5 |
38x51.4x15.4 |
Order information |
Art. no. |
280511 |
280512 |
280515 |